Multi-Parameters Monitor
- Company Name:EASTSTAR ENTERPRISE CO.,LTD
- Membership:Free Member
- Member Since:2005. 05.18
- Country/Region:China
- City:Guangdong
- Contact:May Heung
- Related Keywords:Parameters Monitor, Medical, Monitor, ECG, Medical Equipment
Contact us
EASTSTAR ENTERPRISE CO.,LTD
[China]
Features: 1) Color TFT Display,English/Chinese Manual,4 Waveforms 2) Designed Weight-lighter to take, Built-In Battery,Continuously Monitoring 3) Parameters:ECG,Respiration,NIBP,IBP With Two Channels,Double TI,SPO2, 4) EtCO2,CO,Abnormal HB,ST Segment Ayalysis,Networking and Data Exchanging 5) Maximum 72 Hours Graphic and Tabular Trends Of All Parameters with Audioable And Visual Alarm 6) Built-in Recorder with numerous print Formats Selectable ________________________________________ Specifications: Safety BM-9000 colorful and easy-taken multi-parameters monitor has the same safty standards which agrees with the standards of IEC60601 Groups and GB9706 Dimension and Weight Dimension: 318mm(W)*152mm(D)*264mm(H) Weight: 5.4kgs Operation Environments Power Requirements: 100-250V/AC, 50/60 Hz Application Scope: Neonatal, pediatric, and adult patients Performance Specifications Display: Colorful TFT display resolution: 640*480 Language:English Indicator: 6-waveform; Alarm Indicator; AC Power Indicator; QRS beep and Alarm Sound Interface: Parameter module interface; AC Power input socket; External VGA interface; Two display mode; Simulative signals output Battery: Rechargable, supplying power more than 2 hours Trend time: 1~72 hours Alarm: User-adjustable high limit and low limit, 3 Level Audible and Visual Alarming Recorder: Built-in thermal printing system Plethysmogram waveform: 2 channels Recording modes: manual,alarm,timing Printing speed: 25mm/s, 50mm/s Network: Connection to center monitor system ECG Specifications 5-lead or 3-lead selectable Lead Input: 5-lead: RA; LA; RL; LL; V Lead mode: I; II; III; avR; avL; avF; V1-V6; CAL Scanning Speed: 12.5 mm/s; 25mm/s; 50mm/s Gain selection: *0.25; *0.5; *1; *2; auto Heart Beating Rate: Adult: 15-300bpm, Pediatric/Neonate: 15-350bpm Accuracy: ±1bpm Resolution: 1bpm Leakage: Less than 10μA Protection: Isolation of Voltage AC4000V/50Hz, Resistance Against Defibrillator/Electronic knives and skin voltage Scaling signal: 1mV/±5% Band width: 0.05-100Hz Alarm range: 15-350bpm ST detection: YES Measurement range: -2.0mV~2.0mV Alarm range: -2.0mV~2.0mV Analysis & Recall of Abnormal HEART BEATING: YES Alarm: Audible and visual alarms/recall Respiration Specifications Mode: RA-LL impedance Range: Adult: 0-120rpm; Pediatric/Neonate: 0-150rpm Resolve Rate: 1rpm Accuracy: ±2rpm Alarm range: 0~120rpm Apnea alarming: YES NIBP Specifications Measurement Method: Auto surge mode Operation model: Manual/Automatic/Continuous Auto measure time: selectable Measurement unit: mmHg/Kpa selectable Alarm: Systolic, Diastolic, Mean Measurement range: Adult: 10~270mmHg; pediatric: 10~200mmHg; Neonate: 10~135mmHg Over-pressure protection: yes Resolution rate: 1bpm Accuracy: ±1rpm Pulse Alarm: 0-254bpm Temperature Specifications Measurement range: 0~50°C Resolution: 0.1°C Accuracy: ± 0.1°C Alarm range: 0~50°C Channel: 2 channel Display: T1; T2; △T IBP Specifications Measure range: -10~300mmHg Resolution: 1mmHg Channel: 2 Alarming range: -10~300mmHg Accuracy: ±2% Pressure names: ART, PA, CVP, RAP, LAP, ICP Pressure sensors: sensitivity:5uV/mmHg Impedance range:300~3000Ω Cardiac Output Specifications Method: thermodilution Cardiac output: 0.1-20 litres/min TB: 23~43'C TI: 0~27'C Resolution: Cardiac output: 0.1 litres/min Blood temp.: ±0.1'C Injection temp.:±0.1'C Parameter output: cardiac output and hemodynamic calculation SpO2 Specifications Measurement range: 0~100% Resolution: 1% Accuracy: ±2% (70~100%); ±3%(40~69%) Alarm range: 0~100% Pulse Rate: Range: 0~250bpm Alarming Range:0~100% Pulse Range: 0~254bpm Resolution: 1bpm Accuracy: ±1bpm Pulse Alarm: 0~254bpm EtCO2 Specifications Method: sidestream Measurement range: EtCO2:0~99mmHg AwRR: 0~150rpm Resolution: EtCO2:1mmHg Resolution rate: 1rpm Accuracy: CO2: ±2mmHg(0~40 mmHg); ±5% reading(41~26 mmHg); ±10% reading(77~99 mmHg) respiration rate:±2 rpm Alarming range: same as measurment range
Other products from this supplier
Browse: Manufacturer Directory Premium Suppliers Site Map
About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy
Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese
Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838